- New Portable communication protocol analyzer (LE-2500/LE-3500/LE-8200)
- Questions Questions about model selection
- Which model has to be chosen?
- Do you have a RS-232C monitor (with simulation function)?
- Can I monitor RS-422/485?
- Is there any model that can monitor communications of RS-232C/RS-422 between devices, PCs or sequencers at speed of 19.2Kbps?
- Can LE-8200 support 1Mbps, 1.05Mbps etc. as it can support any baud rate up to 4Mbps?
- Is there any protocol analyzer that can monitor RS-232C, RS-422 (1Mbps) and RS-485 (4Mbps)?
- I want to perform long time continuous logging anyhow.
- Is a dedicated cable necessary to monitor a PC and a device?
- Do you have an analyzer for 3-wire clock communications between LSI?
- Do you have a monitoring device for I2C bus?
- Do you have a monitoring device for SPI bus?
- Do you have an analyzer which can measure TTL, 500Kbps, ASYNC, half-duplex (not RS-232C but serial communications of TTL)?
- Is it possible to simulate communications of SPI and I2C by using LE-2500, LE-3500 or LE-8200 with OP-SB5F or OP-SB5G or OP-SB85?
If it is possible, is master/slave of clock supported?
- Do you have an analyzer that supports the multi-processor communications?
- Do you have an analyzer that have a function for internally creating clocks from TxD/RxD communication at HDLC (NRZI)?
- I want to monitor HDLC communications by using LE-2500/LE-3500/LE-8200, but the device being measured does not output the clocks.
In this case, is the monitoring possible?
- I want to capture the data monitored by the protocol analyzer into the PC.
- Please advise me the difference between LE-2500/LE-3500/LE-8200 packages for Japan and for overseas.
- Questions about measurement function
- Is the monitored data of LE-2500/LE-3500/LE-8200 saved when turning off the power?
- Is it possible to save the data on the memory card of LE-2500/LE-3500/E-8200, and capture that data to the PC?
- Please inform me the pin assignment for RS-422/485 port of LE-2500/LE-3500/LE-8200.
- Is it possible to output the transmission data monitored on LE-2500/LE-3500/LE-8200 by simulation mode?
- By using LE-2500/LE-3500/LE-8200, is it possible to measure operating time of the communication time between A unit and B unit in resolution of 0.1 second for the operating time measurement between RS-232C protocol?
- After transmitting SD:'A' by LE-2500/LE-3500/LE-8200, is it possible to display the time until RD:'B' is received?
- Is it possible to measure the throughput for a device by using LE-2500/LE-3500/LE-8200?
- What kind of method to calculate horizontal parity check is possible?
- Is it possible to specify the data for CRC calculation?
- I would like to save the data before and behind the trigger when the trigger factor is generated repeatedly. How can I do that?
- How much is the error range of the baud rate for LE-2500/LE-3500/LE-8200?
- Is the character synchronous (1616H) mode of NRZI possible on LE-2500/3500/8200?
- Is the block check code (such as CRC) of transmission data generated automatically when LE-2500/3500/8200 is in simulation?
- When monitoring data of LE-2500/LE-3500/LE-8200, monochrome reversing "B" is output on the LED. What does it mean? Also, when does it happen?
- What is "Break"?
- What does Break signal mean?
- What does "BERT function based on ITU-T G.821 advice" mean?
- What is the framing error?
- What is the pin connection like when monitoring RS-485 by using LE-2500/ LE-3500/LE-8200?
- Is it possible to monitor (or distinguish in some methods) whether it is in which state of "mark" or "flag data" on the lines when monitoring HDLC communications by using LE-2500/LE-35000/LE-8200?
- What is IDLE MOD on the settings when monitoring HDLC communication of RS-485 by using LE-2500/LE-3500/LE-8200?
- As for the idle time displaying function for LE-2500/LE-3500/LE-8200, what is the state of non-communications? Also, if the setting is 1msec, is the idle time of 0.99msec displayed?
- Is it possible to record RS232C control lines (RTS, CTS, DTR etc.) by using LE-2500/LE-3500/LE-8200?
- What kind of setting is the item of APPEND of AUTO SAVE setting on LE-2500/LE-3500/LE-8200?
- I would like to perform the trigger to the error (for example, abort) on LE-2500/LE-3500/LE-8200, and externally output the raw signal of that time.
(I would like to monitor the waveform at the time of the error by external oscilloscope.)
- There are the times when the length of the stop bit of communication data of which I would like to perform the monitor display on LE-2500/LE-3500/LE-8200 is 1BIT and 2BIT.(They are not intermingled at the same time.)
At this time, can I set the length of STOP BIT? Or, does it automatically recognize?
- Is it possible to switch the monitor display between LSB and MSB?
- There is a feature that can arbitrary set the baud rate to 4 effective digits.As long as the number is 4 digits, any kinds of values are accepted?
Example: Is it possible to monitor 10.42kbps?
- When the data of LE-2500/LE-3500/LE-8200 is saved on an external memory card, what kind of file format is it?
- Is it possible to set CRC (generating polynomial: X^16+X^12+X^5+1) of CITT as the setting item of FCS on LE-2500/LE-3500/LE-8200?
- I would like to monitor the error waveform by using the logic analyzer function and the trigger function of LE-2500/LE-3500/LE-8200.
- I would like to log the data of 1GB by using a 1GB CF card. How should I set?
- Half-duplex transmission of RS-485 is performed on LE-2500/LE-3500/LE-8200. Even if it is possible to transmit, it is not possible to receive.
- Please teach me how to translate the data when the measured data of I2C bus is printed or converted into text format on the PC by using LE-2500/LE-3500/LE-8200.
- Is it possible to set the existence of terminator on LE-2500/LE-3500/LE-8200?
- Please advice me about the control timing of RS-485 driver for rs-485 half-duplex connection when LE-2500/LE-3500/LE-8200 is in the simulation.
- Question About Option, Accessories
- Not working
- Portable communication protocol analyzer (LE-7200/LE-3200/LE-2200/LE-1200)
- Questions Questions about model selection
- Which model has to be chosen?
- Do you have a RS-232C monitor (with simulation function)?
- Can I monitor RS-422/485?
- Is there any model that can monitor communications of RS-232C/RS-422 between devices, PCs or sequencers at speed of 19.2Kbps?
- Can LE-7200 support 1Mbps, 1.05Mbps etc. as it can support any baud rate up to 4Mbps?
- Is there any protocol analyzer that can monitor RS-232C, RS-422 (1Mbps) and RS-485 (4Mbps)?
- I want to perform long time continuous logging anyhow.
- Is a dedicated cable necessary to monitor a PC and a device?
- Do you have an analyzer for 3-wire clock communications between LSI?
- Do you have a monitoring device for I2C bus?
- Do you have a monitoring device for SPI bus?
- Do you have an analyzer which can measure TTL, 500Kbps, ASYNC, half-duplex (not RS-232C but serial communications of TTL)?
- Is it possible to simulate communications of SPI and I2C by using LE-1200, LE-2200, LE-3200 or LE-7200 with OP-SB5F?
If it is possible, is master/slave of clock supported?
- Do you have an analyzer that supports the multi-processor communications?
- Do you have an analyzer that have a function for internally creating clocks from TxD/RxD communication at HDLC (NRZI)?
- I want to monitor HDLC communications by using LE-2200/LE-3200/LE-7200, but the device being measured does not output the clocks.
In this case, is the monitoring possible?
- I want to capture the data monitored by the protocol analyzer into the PC.
- Please advise me the difference between LE-1200/LE-2200/LE-3200/LE-7200 packages for Japan and for overseas.
- Questions about measurement function
- Is the monitored data of LE-1200/LE-2200/LE-3200/LE-7200 saved when turning off the power?
- Is it possible to save the data on the memory card of LE-1200/LE-2200/LE-3200/E-7200, and capture that data to the PC?
- Please inform me the pin assignment for RS-422/485 port of LE-1200/LE-2200/LE-3200/ LE-7200.
- Is it possible to output the transmission data monitored on LE-1200/LE-2200/LE-3200/LE-7200 by simulation mode?
- By using LE-1200/LE-2200/LE-3200/LE-7200, is it possible to measure operating time of the communication time between A unit and B unit in resolution of 0.1 second for the operating time measurement between RS-232C protocol?
- After transmitting SD:'A' by LE-1200/LE-2200/LE-3200/LE-7200, is it possible to display the time until RD:'B' is received?
- Is it possible to measure the throughput for a device by using LE-1200/LE-2200/LE-2300/LE-7200?
- What kind of method to calculate horizontal parity check is possible?
- Is it possible to specify the data for CRC calculation?
- I would like to save the data before and behind the trigger when the trigger factor is generated repeatedly. How can I do that?
- How much is the error range of the baud rate for LE-1200/LE-2200/LE-3200/LE-7200?
- Is the character synchronous (1616H) mode of NRZI possible on LE-2200/3200/7200?
- Is the block check code (such as CRC) of transmission data generated automatically when LE-1200/2200/3200/7200 is in simulation?
- When monitoring data of LE-1200/LE-2200/LE-3200/LE-7200, monochrome reversing "B" is output on the LED. What does it mean? Also, when does it happen?
- What is "Break"?
- What does Break signal mean?
- What does "BERT function based on ITU-T G.821 advice" mean?
- What is the framing error?
- What is the pin connection like when monitoring RS-485 by using LE-1200/LE-2200/ LE-3200/LE-7200?
- Is it possible to monitor (or distinguish in some methods) whether it is in which state of "mark" or "flag data" on the lines when monitoring HDLC communications by using LE-2200/LE-32000/LE-7200?
- What is IDLE MOD on the settings when monitoring HDLC communication of RS-485 by using LE-2200/LE-3200/LE-7200?
- As for the idle time displaying function for LE-1200/LE-2200/LE-3200/LE-7200, what is the state of non-communications? Also, if the setting is 1msec, is the idle time of 0.99msec displayed?
- Is it possible to record RS232C control lines (RTS, CTS, DTR etc.) by using LE-1200/LE-2200/LE-3200/LE-7200?
- What kind of setting is the item of APPEND of AUTO SAVE setting on LE-1200/LE-2200/LE-3200/LE-7200?
- I would like to perform the trigger to the error (for example, abort) on LE-1200/LE-2200/LE-3200/LE-7200, and externally output the raw signal of that time.
(I would like to monitor the waveform at the time of the error by external oscilloscope.)
- There are the times when the length of the stop bit of communication data of which I would like to perform the monitor display on LE-1200/LE-2200/LE-3200/LE-7200 is 1BIT and 2BIT.(They are not intermingled at the same time.)
At this time, can I set the length of STOP BIT? Or, does it automatically recognize?
- Is it possible to switch the monitor display between LSB and MSB?
- There is a feature that can arbitrary set the baud rate to 4 effective digits.As long as the number is 4 digits, any kinds of values are accepted?
Example: Is it possible to monitor 10.42kbps?
- When the data of LE-1200/LE-2200/LE-3200/LE-7200 is saved on an external memory card, what kind of file format is it?
- Is it possible to set CRC (generating polynomial: X^16+X^12+X^5+1) of CITT as the setting item of FCS on LE-1200/LE-2200/LE-3200/LE-7200?
- I would like to monitor the error waveform by using the logic analyzer function and the trigger function of LE-1200/LE-2200/LE-3200/LE-7200.
- I would like to log the data of 1GB by using a 1GB CF card. How should I set?
- Half-duplex transmission of RS-485 is performed on LE-1200/LE-2200/LE-3200/LE-7200. Even if it is possible to transmit, it is not possible to receive.
- Please teach me how to translate the data when the measured data of I2C bus is printed or converted into text format on the PC by using LE-2200/LE-3200/LE-7200.
- Is it possible to set the existence of terminator on LE-1200/LE-2200/LE-3200/LE-7200?
- Please advice me about the control timing of RS-485 driver for rs-485 half-duplex connection when LE-1200/LE-2200/LE-3200/LE-7200 is in the simulation.
- Question About Option, Accessories
- Not working
- Portable Communication Protocol Analyzer (Previous Version)(LE-7000/LE-3100/LE-2100/LE-1100)
- PC-connectable Communication Protocol Analyzer(LE-150P/LE-150L)
- USB Protocol Analyzer(LE-620HS/LE-610FS/LE-600S)
- Interface Converter
- Questions about purchase